>Product Description
Inorganic material-based insulation material in granulometric powder form, modified with minerals, for thermal, water, sound insulation and fire resistance which is applied in plaster form on to the building walls directly without any extra process.- Color: White
>Application Fields
Applied on to the exterior or interior wall of both new and old buildings in order to provide insulation.Applicable to following surfaces;
- Brick
- Aerated Concrete
- Pumice Block / Brick
- Precast Concrete
- Concrete
- Natural Stone
Performance Values
Durum | DeÄŸer |
---|---|
Dry Bulk Weight: | 330 kg/m3 +/- 30 |
Thermal Conductivity: | 0,041 W/mK (T1) |
Reaction to Fire Class: | A1 |
Capillary Water absorption: | 0,2 (W1) |
Vapor Permeability Coefficient | < 4,7 |
Compressive Strength: | 1,3 MPa (CSI) |
Flexural Strength: | 0,6 MPa |
Adhesion to Substrate: | 0,32 N/mm2 - 100% CF-A |
>Application Thickness
Application thickness is determined in accordance to the regional weather conditions, wall structure and insulation level required or demanded. So our experts will assist you to determine the suitable application thickness for your building.Limitations for Application Thickness:
- Minimum Application Thickness: 5 mm
- Maximum Application Thickness: 100 mm
- Maximum thickness to be used at a time: 30 mm
- (For the thickness requirements above 30 mm, it should be waited for 12 hours after each layer. This period can be extended on cold weather conditions.)
Surface Preparation:
- It is required to remove and clean the dust on surface on which insulation material is to be applied.
- It is not required to use any primer or auxiliary material on the surface on which insulation material is to be applied.
- Present paint on surface shall be peeled off from the wall before the application on the old buildings.
>Application Methods
Greenshield Natural Insulation Plaster can be applied by both manually and machine.1.Manual Application
- Pour one package Greenshield into a clean bucket of 30-40 liter
- Add approximately 6-7 liters of water into the bucket.
- Mix it with plaster mixer for 7-8 minutes until it reachs the consistency of plaster, than it is ready to apply.
Resimler: Karıştırma resmi, kıvam resmi. - * In order to provide the required thickness and to have a straight wall, the laths are mounted vertically on to the wall at certain gaps as wide as the straight edge.
- Prepared plaster is applied by a suitable trowel roughly between the laths.
- The surface is leveled by straight edge.
- After the surface absorbs the water in a certain period of time, one of the following processes is performed preferably;
- Alternative 1: Process is finished by leveling the surface with steel trowel.
- Alternative 2: Process is finished by applying 1-3 mm thick decorative plaster to the surface as a finishing coat. Resimler: El ile sıva uygulanırken, mastar çekilirken
Machine application
Material can also be applied to the surfaces by plastering machines. It is not required any other special machine.- In order to provide the required thickness and to have a straight wall, the laths are mounted vertically on to the wall at certain gaps as wide as the straight edge.
- One pack of product is poured into the plastering machine.
- The automatic water adjustment is the most important point here. Approximately 1/3 of the water which is already being used in standard plaster application shall be used in the plastering machine.
- If the water content of the material is too much, the water level is decreased until it becomes thicken like plaster.
- Then, the product roughly poured between laths by machine.
- The surface is leveled by straight edge.
- After the surface absorbs the water in a certain period of time, one of the following processes is performed preferably;
- Alternative 1: Process is finished by leveling the surface with steel trowel.
- Alternative 2: Process is finished by applying 1-3 mm thick decorative plaster to the surface as a finishing coat.
Cautions & Recommendations
- Packs should be used completely while preparing the mixture. The product in each pack should completely be poured.
- It is required to pay attention to the water amount to be added into the mixture. Excessive amount of water should not be added.
- Any different materials other than water should definitely not be added into the mixture.
- The mixture shall be prepared with suitable plastering mixer under low-speed during the recommended period of time.
- Plastering mesh should be used for the buildings having 30-storey and more, against the negative effects of the wind load. In lower buildings it is not required to use plastering mesh.
- Using of plastering mesh is recommended in the applications having thickness of 40 mm and more.
- The ambient temperature for the application should be between +5°C and +35 °C.
>Packaging Info
Durum | DeÄŸer |
---|---|
Net Package Content : | 12 kg of Greenshield Natural Insulation Plaster |
Mode of handling : | Shrink wrapped on Wooden Pallet |
Base Dimension of Pallet Ölçüleri: | 100 x 120 cm |
Pallet Height | 110 – 120 cm |
Packs Per Pallet : | 48 Packs |
Shelf Life : | 12 months* under suitable conditions |
> Consumption Info:
approximately 3,5 – 4,5 kg / sqm per 1 cm thickness.